Morrisville UDO Administrative Manual, 11/1/18 version
Part 4 Appendices 4.5 Checklists
Telecommunications Facility New Tower
New Telecommunication Facility Construction Plan Approval for a Site Plan (Major or Minor) Submittal Checklist For each listed item, check (√) if provided, write “n/a” if the feature does not exist or is not proposed, and write “w” if a waiver from the requirement is justified because it is unnecessary in the particular case to determine compliance with applicable regulations. Staff Use Only √, n/a, or w Application Submittal Requirement √, n/a, or w A Documents to be Submitted
1 This completed checklist 2 Completed application 3 Completed application fee schedule and fee payment 4 Sets of plans – 24 " x36 ", stapled, collated, and folded (8 copies)
5 Elevation and bench marks referenced to National Geodetic Vertical Datum (NGVD) 6 Compact disc of plans with a PDF of each submitted plan sheet and all reports/documents 7 Request for No Practical Alternatives Determination / Request for Buffer Authorization (for any proposed impacts to riparian buffers)
8 Copy of all stream determinations & signed JDs (jurisdictional determinations) 9 No Rise flood study, copy of any CLOMR or LOMR, & Elevation Certificate 10 Stormwater Report B Base Information for Each Plan Sheet
1 Name, address, telephone number, and fax number of Engineer, Architect, or Landscape Architect licensed in the State of North Carolina responsible for the plans 2 Date of drawing preparation and all revision dates 3 Sheet number and title 4 North arrow (except detail and elevation sheets) 5 The scale of the drawings listed in feet per inch in both graphic and numeric scale. Engineering scale no smaller than 1” = 10’ and larger than 1” = 50’ is recommended (except detail & elevation sheets) 6 Seal and signature of Registered Design Professional registered in the State of North Carolina 7 Name of the site in title block 8 Project number and file number in lower right hand corner (numbers assigned once project submitted) C Cover Sheet Information 1 Name of proposed facility and “Construction Plan” or “Site Plan /Construction Plan” if combined review 2 Vicinity map at 1 " = 400 ' with project boundary clearly marked. There must be sufficient detail and legibility to locate the project in reference to nearby roads. 3 The dates, resolution or ordinance number(s), and details of any previously approved rezoning and if applicable, special use permit approval. 4 All general notes 5 Sheet Index (Note: The plan must be in the same order as this checklist) 6 Additional requirements for certain permitted uses per Article 4: Use Standards, of the UDO (if applicable) D Existing Conditions Survey 1 Property lines clearly presented showing all bearings and distances, with an accuracy of closure in accordance with the Standards of Practice in NC GS 4730 from a current survey. Sufficient data must be included to reproduce on the ground every straight or curved boundary line, lot line, right- of-way line, and easement. Survey must be signed and sealed by a North Carolina Licensed Professional Land Surveyor.
2 Names of adjoining property owners and subdivisions 3 Adjoining zoning districts – boundaries and names
4 Jurisdictional boundaries 5 Adjoining current land uses 6 Right(s)-of-way or easement(s) e.g. street, railroad, and utility 7 Street name, right-of-way width, public or private, and state road number 8 Water, sewer, natural gas, and other utility lines
Morrisville, NC