(B) From the road right-of-way line to the equipment compound area fence.
(C) When adjacent to railroad right-of-way, the underlying zoning setback shall prevail.
(2) Screening
DAS Wired Hub facilities and equipment shall be hidden and/or screened from public view by one or more of the following techniques:
(A)
Locate equipment within a building
The building shall be designed to be consistent with the prevailing architectural style of the neighborhood in which it is located, including exterior materials and roof pitch. The enclosure shall not exceed one story, unless location in a flood plain or other drainage concerns requires it to be elevated. (B) Locate equipment behind a secured, fenced area with a landscaped perimeter An evergreen landscape buffer shall surround the perimeter of the DAS Wired Hub per the buffer requirements identified in Section 4.2.5.D.4.g(8) below .
(C)
Roof-top equipment
DAS Wi red Hub equipment shall be screened from public view in a manner that is consistent with the architectural style of the building upon which the DAS Wired Hub is located.
(3) DAS Wired Hub Compound Area
The DAS Wired Hub compound area shall not be used for the storage of any excess equipment or hazardous materials. Outdoor storage yards shall be prohibited within a compound area.
(4) Equipment cabinets and shelters
Cabinets and shelters shall not be visible from pedestrian and vehicular right-of-way views. Cabinets may be provided within the principal building, behind a screen on a rooftop, or on the ground within the fenced-in and screened DAS Wired Hub compound area.
(5) Fencing
The DAS Wired Hub compound area shall be enclosed with an opaque black vinyl-coated fence or wall with an access gate to minimize opportunities for unauthorized access, climbing, vandalism, graffiti and other conditions that would result in hazardous conditions, visual blight and attractive nuisances. The fence or wall shall be no less than the above grade height of any equipment within the compound area, which shall not be taller than one story, unless located in a flood zone. Commercial messages are prohibited on any tower or fencing. Required noncommercial signage shall be subject to the following requirements: (A) The only signage that is permitted upon a DAS Wired Hub or compound area fence shall be informational such as the party responsible for the operation and maintenance of the facility, and any additional security and safety signs as applicable. (B) If more than 220 voltage is necessary for the operation of the facility, signs located every twenty feet and attached to the fence shall display in large, bold, high
(6) Signage