Article 5: Development Standards Section 5.6. Floodplain Management 5.6.5. Standards for Special Flood Hazard Areas with Flood Elevation Data

and/or improvements shall be designed to minimize flood damages and shall not be any more nonconforming than the existing structure. 2. Where additions and/or improvements to pre-FIRM structures, in combination with any interior modifications to the existing structure, constitute a substantial improvement, both the existing structure and the addition and/or improvements shall comply with the standards for new construction. 3. Where additions to post-FIRM structures constitute a substantial improvement and involve no modifications to the existing structure other than a standard door in the common wall, only the addition is required to comply with the standards for new construction. 4. Where additions and/or improvements to post-FIRM structures, in combination with any interior modifications to the existing structure, do not constitute a substantial improvement, only the addition and/or improvements is required to comply with the standards for new construction. 5. Where additions and/or improvements to post-FIRM structures, in combination with any interior modifications to the existing structure, constitutes a substantial improvement, both the existing structure and the addition and/or improvements shall comply with the standards for new construction. 6. Where any combination of repair, reconstruction, rehabilitation, addition, or improvement of a building or structure takes place during a ten-year period and their cumulative cost equals or exceeds 50 percent of the market value of the structure before the improvement or repair is started, the improvement or repair must comply with the standards for new construction. For each building or structure, the ten-year period begins on the date of the first improvement or repair of that building or structure subsequent to the effective date of this Ordinance. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The requirement does not, however, include either: a. Any project for improvement of a building required to correct existing health, sanitary, or safety code violations identified by the Building Official and that are the minimum necessary to assume safe living conditions; or b. Any alteration of a historic structure, provided that the alteration will not preclude the structure’s continued designation as a historic structure. 7. Where an independent perimeter load-bearing wall is provided between the addition and the existing building, the addition(s) shall be considered a separate building and only the addition is required to comply with the standards for new construction. F. Recreational Vehicles Unless a recreational vehicle is on site for fewer than 180 consecutive days and is fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities, and has no permanently attached additions), it shall be required to meet all the requirements for new construction. G. Temporary Nonresidential Structures An application for a Floodplain Development Permit for a temporary nonresidential structure shall include a plan for the removal of such structure in the event of a hurricane, flash flood, or other type of flood warning notification. The plan shall include the following information: 1. A specified time period, not exceeding three months, for which the temporary structure will be permitted, which may be renewed for up to one year; 2. The name, address, and phone number of the individual responsible for the removal of the temporary structure;

Morrisville, NC

February 1, 2021

Unified Development Ordinance

Page 5-26

Made with FlippingBook HTML5