Morrisville Unified Development Ordinance - May 2020
Article 3: ZoningDistricts Section 3.4. Activity Center Districts 3.4.5. Regional Activity Center (RAC) District
Regional Activity Center (RAC) District
3.4.5.
Regional Activity Center (RAC) District
A. Purpose
In accordance with the Comprehensive Plan, the Regional Activity Center District provide s for significant regional employment, retail, education, health care, entertainment or mixed-use destinations at key interchanges/intersections of major transportation corridors in Town. It is also intended to provide improved access to jobs, a compatible mix of uses and access to a variety of transportation options. Land uses should include a mix of uses, such as of office and institutional, entertainment, retail and major commercial land uses. Medium and high density residential uses should be included.
B. Principal Intensity and Dimensional Standards
Cross References
A, etc. are symbols used in the illustrations showing application of dimensional standards
Art. 4: Use Standards Art. 5: Development Standards
Single-Family Attached Dwellings
Multifamily Dwellings
Other Uses
Sec. 5.9.6 Sec. 5.9.7
Lot Standards
Min. Net Lot Area (sf)
n/a
20,000
20,000
A
Min. Lot Width (ft)
20
100
150 n/a
Sec. 5.10.6.B.2 Sec. 5.10.9.G
Max. Net Density (du/ac) Max. Lot Coverage (%)
no maximum
no maximum
70
65
65
Art. 6: Riparian Buffers
Setbacks
Art. 7: Stormwater Management
B1 Min. Front (ft) B2
Alley-loaded
10 [1]
n/a
n/a
Other
20
30
30
Min. Side (ft)
0
10
10
C
Min. Corner Side (ft)
18
30
30
D
E1 Min. Rear (ft) E2
Alley-loaded
6 [1]
n/a
n/a
Other
10
20
20
Building Standards F 1 Max. Structure Height (ft) F 2 Min. Structure Height (stories)
45
60
100
no minimum
3 [2][3]
no minimum
25
G
Min. Building Separation (ft) n/a Notes: sf = square feet; ft = feet; du = dwelling unit; ac = acre; % = percent; n/a = not applicable [1] Setbacks also apply to residential developments with detached front-loaded garages located to the rear of the principal structure. [2] Applied to multifamily developments. See additional standards in Section 5.9.8.C.1, Minimum Height. [3] The minimum structure height for a carriage–style building with multifamily dwellings over garages is two stories. (Ord. No. 2014-022, 06/24/2014; Ord. No. 2016-001, 05/10/2016) n/a
Morrisville, NC
May 26, 2020
Unified Development Ordinance
Page 3-22