UDO Adopted Version July 2024
Article 5: Development Standards Section 5.7. Perimeter and Streetyard Buffers 5.7.4. Buffer Type Standards
Buffer Type Standards
5.7.4.
Table 5.7.4: Buffer Type Standards, describes five types of perimeter buffer and six different types of streetyard buffer in terms of their function, opacity, width, and screening requirements.
Table 5.7.4: Buffer Type Standards Minimum Width and Screening Requirements Also see general requirements for all buffer types at bottom of table. Buffer Type A (Perimeter) This perimeter buffer provides a continuous opaque screen to a height of at least six feet. It serves as a visual and noise barrier between developments on adjoining properties.
•
Shade trees: 6 per 100 linear feet, with at least 5 feet between mature canopies
• •
Understory trees: 4 per 100 linear feet
Option 1
Evergreen shrubs: 20 per 100 linear feet and at least 6 feet high at maturity At least 50% of all trees must be evergreen
•
•
Shade trees: 5 per 100 linear feet, with at least 5 feet between mature canopies
• •
Understory trees: 3 per 100 linear feet
Option 2
Evergreen shrubs: 15 per 100 linear feet and at least 3 feet high at maturity A solid fence or wall at least 6 feet high [1] At least 50% of all trees must be evergreen
• •
Morrisville, NC
July 9, 2024 Page 5-32
Unified Development Ordinance
Made with FlippingBook Annual report maker